Description
The default variable for sync_binlog is 0 for MariaDB, where Oracle changed it to 1 starting with 5.7.7. I think we should also change the default to 1, as running a master with sync_binlog=0 is risky - any crash of server or mysqld will create inconsistent slaves 99% of the time.
Attachments
Issue Links
- is blocked by
-
MDEV-18959 Engine transaction recovery through persistent binlog
- Stalled
-
MDEV-24386 MDEV-16589 benchmark & analysis
- Closed
- relates to
-
MDEV-34705 Storing binlog in InnoDB
- In Progress