Details
-
Bug
-
Status: Closed (View Workflow)
-
Minor
-
Resolution: Fixed
-
10.0(EOL), 10.1(EOL), 10.2(EOL), 10.3(EOL), 10.4(EOL)
-
None
Description
http://buildbot.askmonty.org/buildbot/builders/kvm-fulltest/builds/5931/steps/test_7/logs/stdio
CURRENT_TEST: multi_source.info_logs
|
--- /mnt/buildbot/build/mariadb-10.1.14/mysql-test/suite/multi_source/info_logs.result 2016-05-06 14:03:15.000000000 +0300
|
+++ /mnt/buildbot/build/mariadb-10.1.14/mysql-test/suite/multi_source/info_logs.reject 2016-05-06 19:49:25.000000000 +0300
|
@@ -86,7 +86,7 @@
|
show all slaves status;
|
Connection_name Slave_SQL_State Slave_IO_State Master_Host Master_User Master_Port Connect_Retry Master_Log_File Read_Master_Log_Pos Relay_Log_File Relay_Log_Pos Relay_Master_Log_File Slave_IO_Running Slave_SQL_Running Replicate_Do_DB Replicate_Ignore_DB Replicate_Do_Table Replicate_Ignore_Table Replicate_Wild_Do_Table Replicate_Wild_Ignore_Table Last_Errno Last_Error Skip_Counter Exec_Master_Log_Pos Relay_Log_Space Until_Condition Until_Log_File Until_Log_Pos Master_SSL_Allowed Master_SSL_CA_File Master_SSL_CA_Path Master_SSL_Cert Master_SSL_Cipher Master_SSL_Key Seconds_Behind_Master Master_SSL_Verify_Server_Cert Last_IO_Errno Last_IO_Error Last_SQL_Errno Last_SQL_Error Replicate_Ignore_Server_Ids Master_Server_Id Master_SSL_Crl Master_SSL_Crlpath Using_Gtid Gtid_IO_Pos Replicate_Do_Domain_Ids Replicate_Ignore_Domain_Ids Parallel_Mode Retried_transactions Max_relay_log_size Executed_log_entries Slave_received_heartbeats Slave_heartbeat_period Gtid_Slave_Pos
|
Slave has read all relay log; waiting for the slave I/O thread to update it Waiting for master to send event 127.0.0.1 root MYPORT_1 60 master-bin.000001 <read_master_log_pos> relay.000002 <relay_log_pos> master-bin.000001 Yes Yes 0 0 <read_master_log_pos> <relay_log_space1> None 0 No 0 No 0 0 1 No conservative 0 1073741824 7 0 60.000
|
-MASTER 2.2 Slave has read all relay log; waiting for the slave I/O thread to update it Waiting for master to send event 127.0.0.1 root MYPORT_2 60 master-bin.000001 <read_master_log_pos> relay-master@00202@002e2.000002 <relay_log_pos> master-bin.000001 Yes Yes 0 0 <read_master_log_pos> <relay_log_space2> None 0 No 0 No 0 0 2 No conservative 0 1073741824 7 0 60.000
|
+MASTER 2.2 Slave has read all relay log; waiting for the slave I/O thread to update it Waiting for master to send event 127.0.0.1 root MYPORT_2 60 master-bin.000001 <read_master_log_pos> relay-master@00202@002e2.000002 <relay_log_pos> master-bin.000001 Yes Yes 0 0 <read_master_log_pos> 885 None 0 No 0 No 0 0 2 No conservative 0 1073741824 7 0 60.000
|
include/wait_for_slave_to_start.inc
|
set default_master_connection = 'MASTER 2.2';
|
include/wait_for_slave_to_start.inc
|
 |
mysqltest: Result length mismatch
|
It happens rather rarely.
Attachments
Issue Links
- blocks
-
MDEV-7069 Fix buildbot failures in main server trees
- Stalled
- is duplicated by
-
MDEV-14478 multi_source.info_logs failed in buildbot, results mismatch
- Closed
- relates to
-
MDEV-4633 multi_source.simple test fails sporadically
- Closed
-
MDEV-10690 multi_source.reset_slave failed in buildbot
- Closed
-
MDEV-21290 multi_source.info_logs test fails
- Confirmed