Uploaded image for project: 'MariaDB Connector/ODBC'
  1. MariaDB Connector/ODBC
  2. ODBC-160

Connector did not set length of SQL_IDENTIFIER_QUOTE_CHAR info

Details

    • Bug
    • Status: Closed (View Workflow)
    • Major
    • Resolution: Fixed
    • 2.0.17, 3.0.5
    • 3.0.6, 2.0.18
    • General
    • None

    Description

      If application requested SQLGetInfo(SQL_IDENTIFIER_QUOTE_CHAR), connector would not set length of the returned string. Particularly, if length buffer was initialized with 0, the value would stay 0.
      This information used by many applications to generate query texts

      Attachments

        Activity

          The commit fe2dc81 has been pushed into odbc-3.0 and merged into master. Yet to be merged into odbc-2.0

          Lawrin Lawrin Novitsky added a comment - The commit fe2dc81 has been pushed into odbc-3.0 and merged into master. Yet to be merged into odbc-2.0

          People

            Lawrin Lawrin Novitsky
            Lawrin Lawrin Novitsky
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved:

              Git Integration

                Error rendering 'com.xiplink.jira.git.jira_git_plugin:git-issue-webpanel'. Please contact your Jira administrators.