Type:
Bug
-
Status: Closed (View Workflow)
-
Priority:
Major
-
Resolution: Fixed
-
Affects Version/s: 10.1, 10.2, 10.3, 10.4
-
Component/s: Platform Windows, Tests
-
Labels:None
There are race conditions in those test, since they depend on "instant drop" of a connection upon MTR "disconnect" command. The connection may hang around for a while still, and it is not certain when socket is going to be closed.
- relates to
-
MDEV-15677 perfschema.socket_connect failed in buildbot with wrong result
-
- Closed
-
-
MDEV-16270 main.connect failed in buildbot with wrong Max_used_connections
-
- Closed
-