Combo installation: After shutdownsystem, first startsystem always fails

    XMLWordPrintable

Details

    • Bug
    • Status: Closed (View Workflow)
    • Critical
    • Resolution: Fixed
    • 1.4.2
    • 1.4.4
    • installation
    • None
    • 2020-3, 2020-4, 2020-5, 2020-6

    Description

      Build tested: 1.4.2-1 (Azure build 20191224.6)

      2pm combo configuration
      non-distributed installation
      root user

      After shutdown the system, the first startsystem command always fails. Running startsystem again would succeed.

      mcsadmin> startsystem vagrant
      startsystem Mon Dec 30 20:25:52 2019

      startSystem command, 'columnstore' service is down, sending command to
      start the 'columnstore' service on all modules

      System being started, please wait...ERROR: Connection refused

      Invalid Password when running 'columnstore start' on module pm2, can retry by providing password as the second argument

            • startSystem Failed

      Same behavior with or without a password provided.