Uploaded image for project: 'MariaDB Connector/J'
  1. MariaDB Connector/J
  2. CONJ-247

Failing to correctly identify CST(TimeZone)

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Closed (View Workflow)
    • Priority: Critical
    • Resolution: Not a Bug
    • Affects Version/s: 1.3.3, 1.3.4
    • Fix Version/s: 1.5.1-RC
    • Component/s: Other
    • Labels:
      None
    • Environment:
      java version "1.7.0_75"
      10.0.21-MariaDB

      Description

      Environment:
      The System TimeZone is UTC +8:00 - CST(China Standard Time)
      mariadb:
      SHOW VARIABLES LIKE '%time_zone%';
      system_time_zone CST
      time_zone SYSTEM

      It happens when i create a preparedStatement and set a timestamp value

       
      private Timestamp occurTime;
       
       public Timestamp getOccurTime() {
              return occurTime;
          }
       
          public void setOccurTime(Timestamp occurTime) {
              this.occurTime = occurTime;
          }
       
       public void convertToStatement(PreparedStatement preparedStatement) throws SQLException {
        preparedStatement.setTimestamp(1, occurTime);
      }

      The correct value is '2016-1-12 10:00:45 257452' AND The value in _stmt(preparedStatement ) is '2016-1-11 20:00:45 257452'

      The gap is 14 hours ,So is it convert incorrectly to Central Standard Time (UTC -6:00)?

        Attachments

          Activity

            People

            Assignee:
            diego dupin Diego Dupin
            Reporter:
            Meedly Tong Wang
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved:

                Git Integration

                Error rendering 'com.xiplink.jira.git.jira_git_plugin:git-issue-webpanel'. Please contact your Jira administrators.