Details
-
Bug
-
Status: Open (View Workflow)
-
Major
-
Resolution: Unresolved
-
12.3
-
None
Description
rpl.rpl_shutdown_wait_semisync_slaves fails on 12.3 with Found warnings/errors in server log file!: the slave error log contains the ERROR line Master server does not read semi-sync messages.
Build Run Info
| Branch | Builder name | Date | Commit | Variant |
|---|---|---|---|---|
| 12.3 | amd64-ubuntu-2204-debug | 2026-10-06T17:30:22Z | fffe55f39cef9e077112f5e9abde3d8dd11ba492 | row |
Failure text
rpl.rpl_shutdown_wait_semisync_slaves 'row' w21 [ fail ] Found warnings/errors in server log file!
|
Test ended at 2026-10-06 15:34:36
|
line
|
2026-10-06 15:34:29 8 [ERROR] Master server does not read semi-sync messages last_error: (1160). Fallback to asynchronous replication
|
^ Found warnings in /home/buildbot/amd64-ubuntu-2204-debug/build/mysql-test/var/21/log/mysqld.2.err
|
ok
|
|
|
- saving '/home/buildbot/amd64-ubuntu-2204-debug/build/mysql-test/var/21/log/rpl.rpl_shutdown_wait_semisync_slaves-row/' to '/home/buildbot/amd64-ubuntu-2204-debug/build/mysql-test/var/log/rpl.rpl_shutdown_wait_semisync_slaves-row/'
|
|
|
Retrying test rpl.rpl_shutdown_wait_semisync_slaves, attempt(2/3)...
|
The failure text is identical in the other two matching runs between 2026-10-02 and 2026-10-09, apart from worker id, timestamps, paths and variant: bb-10.11-pranav-MDEV-39343 on s390x-ubuntu-2204-debug (2026-10-05T11:21:58Z, variant row) and refs/pull/4817/head on amd64-ubuntu-2204-debug-ps (2026-10-06T10:08:38Z, variant stmt).
Analysis
Three distinct builders on two architectures are affected (amd64-ubuntu-2204-debug, amd64-ubuntu-2204-debug-ps and s390x-ubuntu-2204-debug), which points at the test rather than at a builder. The slave IO thread logs this message at ERROR level in sql/slave.cc when Repl_semi_sync_slave::slave_reply() fails and the thread was not killed. The test runs SHUTDOWN WAIT FOR ALL SLAVES on the master while semi-sync is enabled on the master and on server_2 and server_3, so a slave that sends its ACK after the master has closed the connection most likely takes this path; the log line reports error 1160 (ER_NET_ERROR_ON_WRITE). The test suppresses only Timeout waiting for reply of binlog on the master, while rpl_semi_sync_slave_reply_fail suppresses Master server does not read semi-sync messages*. The same message for a stopping slave was handled in MDEV-32943, and the code path is analysed in MDEV-40958.
Created via the mtr-failure-bug skill.
Attachments
Issue Links
- relates to
-
MDEV-40415 Address replication MTR test failures
-