Details
-
Bug
-
Status: Closed (View Workflow)
-
Major
-
Resolution: Fixed
-
10.5.11, 10.6.3
-
None
Description
DC1 :-
vmc11, vmc12, vmc13
DC2
vmc21 , vmc22 , vmc 23
Unidirectional Replication :-
vmc11 (server_id=1 and wsrep_gtid_domain_id=1 )--> vmc 21 (server_id=2 and wsrep_gtid_domain_id=2 )
|
|
1. Enable WSREP GTID parameters on all node of the Galera cluster
vmc11
|
MariaDB [(none)]> select @@gtid_domain_id, @@server_id, @@wsrep_gtid_domain_id,@@wsrep_gtid_mode;
|
+------------------+-------------+------------------------+-------------------+
|
| @@gtid_domain_id | @@server_id | @@wsrep_gtid_domain_id | @@wsrep_gtid_mode |
|
+------------------+-------------+------------------------+-------------------+
|
| 11 | 1 | 1 | 1 |
|
+------------------+-------------+------------------------+-------------------+
|
For vmc12 gtid_domain_id=12 and vmc13 gtid_domain_id=13 rest all same as mentioned above.
|
2. Bootstrap one node.
|
3. Perform some DDL or DML transactions on vmc11
|
4. Check GTID value, its as expected one (No issue).
|
5. Take mariabackup and restore the same on another DC node 1 of galera cluster.
|
6. Stop service--> remove data dir content--> copy back --> change ownership --> bootstrap with galera_new_cluster
|
7. Another Cluster node is having server_id and wsrep_gtid_domain_id as 2
|
|
vmc21
|
MariaDB [(none)]> select @@gtid_domain_id, @@server_id, @@wsrep_gtid_domain_id,@@wsrep_gtid_mode;
|
+------------------+-------------+------------------------+-------------------+
|
| @@gtid_domain_id | @@server_id | @@wsrep_gtid_domain_id | @@wsrep_gtid_mode |
|
+------------------+-------------+------------------------+-------------------+
|
| 21 | 2 | 2 | 1 |
|
+------------------+-------------+------------------------+-------------------+
|
|
8. Perform some DDL or DML transactions on local node vmc21
9. Check the GTID value, not expected value (local transactions get stored with server_id=1 and wsrep_gtid_domain_id=1 while local node server_id=2 and wsrep_gtid_domain_id=2)
10. Now lets enable the Replication from vmc11-->vmc21 with GTID.
11. Perform some DDL or DML transaction again on vmc11
12. Check the GTID value , expected value.
13. Lets perform local transaction again on vmc21
|
MariaDB [(none)]> select @@hostname;
|
+------------+
|
| @@hostname |
|
+------------+
|
| vmc21 |
|
+------------+
|
1 row in set (0.000 sec)
|
|
MariaDB [(none)]> create database sbtest100;
|
Query OK, 1 row affected (0.001 sec)
|
|
MariaDB [(none)]> drop database sbtest100;
|
Query OK, 0 rows affected (0.002 sec)
|
|
MariaDB [(none)]> show binlog events in 'mysql-bin.000002' from 892;
|
+------------------+------+------------+-----------+-------------+---------------------------+
|
| Log_name | Pos | Event_type | Server_id | End_log_pos | Info |
|
+------------------+------+------------+-----------+-------------+---------------------------+
|
| mysql-bin.000002 | 892 | Gtid | 1 | 934 | GTID 1-1-3 |
|
| mysql-bin.000002 | 934 | Query | 1 | 1036 | create database sbtest100 |
|
| mysql-bin.000002 | 1036 | Gtid | 1 | 1078 | GTID 1-1-4 |
|
| mysql-bin.000002 | 1078 | Query | 1 | 1178 | drop database sbtest100 |
|
+------------------+------+------------+-----------+-------------+---------------------------+
|
|
vmc21 :- GTID value consist of server_id and wsrep_gtid_domain_id of vmc11 i.e 1 and 1 while local server_id and wsrep_gtid_domain_id is 2 .
Attachments
Issue Links
- relates to
-
MDEV-26237 Actual GTID value missing with Mariabackup when "wsrep_gtid_mode=ON"
- Closed
-
MDEV-26223 Galera cluster node consider old server_id value even after modification of server_id [wsrep_gtid_mode=ON]
- Closed