Details
-
Bug
-
Status: Closed (View Workflow)
-
Major
-
Resolution: Fixed
-
6.4.10
-
MXS-SPRINT-192
Description
server4 | 2023-10-05 8:42:04 49 [ERROR] Error reading packet from server: Unknown command (server_errno=1047)
|
server4 | 2023-10-05 8:42:04 49 [Note] Slave I/O thread: Failed reading log event, reconnecting to retry, log 'binlog.000002' at position 3948; GTID position '0-3000-27'
|
server1 | 2023-10-05 8:42:04 13 [ERROR] Read semi-sync reply magic number error
|
server1 | 2023-10-05 8:42:04 73 [Note] Start binlog_dump to slave_server(3003), pos(binlog.000002, 3948), using_gtid(1), gtid('0-3000-27')
|
server1 | 2023-10-05 8:42:04 72 [Note] Stop semi-sync binlog_dump to slave (server_id: 3003)
|
Attachments
Issue Links
- relates to
-
MDEV-32551 "Read semi-sync reply magic number error" warnings on master
- Closed