Description
If one tries to connect with an incorrect password, the connection is aborted, one has to connect again to try a new password. But if one tries an incorrect password with the COM_CHANGE_USER command, he is not disconnected, which allows to brute-force passwords faster. Additionally, all COM_CHANGE_USER issued in a connection use the same scramble value.
We can fix it by allowing only three (or any other small fixed number?) of failed COM_CHANGE_USER in a connection.
It probably shouldn't be "three fails in a row", because one would be able to alternate between two known accounts and continue trying other password.