[MXS-2040] Default monitor timeouts are too short Created: 2018-09-10  Updated: 2018-09-11  Resolved: 2018-09-11

Status: Closed
Project: MariaDB MaxScale
Component/s: mariadbmon, Monitor
Affects Version/s: 2.2.1
Fix Version/s: 2.2.14

Type: Bug Priority: Minor
Reporter: Esa Korhonen Assignee: Esa Korhonen
Resolution: Fixed Votes: 0
Labels: None


 Description   

backend_read_timeout is one second by default, which often causes problems with switchover/failover. All three timeouts are now three seconds.