[MCOL-3704] Combo installation: After shutdownsystem, first startsystem always fails Created: 2019-12-30 Updated: 2020-03-30 Resolved: 2020-03-30 |
|
| Status: | Closed |
| Project: | MariaDB ColumnStore |
| Component/s: | installation |
| Affects Version/s: | 1.4.2 |
| Fix Version/s: | 1.4.4 |
| Type: | Bug | Priority: | Critical |
| Reporter: | Daniel Lee (Inactive) | Assignee: | Daniel Lee (Inactive) |
| Resolution: | Fixed | Votes: | 0 |
| Labels: | None | ||
| Sprint: | 2020-3, 2020-4, 2020-5, 2020-6 |
| Description |
|
Build tested: 1.4.2-1 (Azure build 20191224.6) 2pm combo configuration After shutdown the system, the first startsystem command always fails. Running startsystem again would succeed. mcsadmin> startsystem vagrant startSystem command, 'columnstore' service is down, sending command to System being started, please wait...ERROR: Connection refused Invalid Password when running 'columnstore start' on module pm2, can retry by providing password as the second argument
Same behavior with or without a password provided. |
| Comments |
| Comment by Ben Thompson (Inactive) [ 2020-03-09 ] |
|
This got merged after the 1.4.3 fixes last week and should be in develop / develop-1.4 now too |
| Comment by Daniel Lee (Inactive) [ 2020-03-30 ] |
|
Builds verified: 1.4.4-1 source 1.4.4-1 /root/ColumnStore/buildColumnstoreFromGithubSource/server /root/ColumnStore/buildColumnstoreFromGithubSource/server/engine Merge pull request #1117 from drrtuy/ |