Uploaded image for project: 'MariaDB MaxScale'
  1. MariaDB MaxScale
  2. MXS-706

LOAD DATA LOCAL INFILE fails when inserting binary data

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Closed (View Workflow)
    • Priority: Minor
    • Resolution: Won't Fix
    • Affects Version/s: 1.4.3, 2.1.9, 2.2.0
    • Fix Version/s: N/A
    • Component/s: readconnroute
    • Labels:
      None

      Description

      When binary data with hexadecimal value '\x11' is loaded through the readconnroute, it misinterprets the loaded data as a COM_CHANGE_USER command. This will cause an error which closes the client connection.

      This could be fixed by adding more parsing into the readocnnroute so that it can detect the LOAD DATA LOCAL INFILE command.

        Attachments

          Activity

            People

            Assignee:
            Unassigned
            Reporter:
            markus makela markus makela
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved: